Before
switching on the generator, connect the filter and the water tube correctly. If
you put the water tube in a bucket, always pay attention that the water in the
bucket does not end. 1) Plug in the generator (the boiler power is 3000 watt) 2)
Switch on
the boiler by pressing the button boiler, the red light will go on and the
process of filling in the generator with water will begin. This process usually
lasts about 4 minutes. 3)
When the
water covers the probe, which is inside the glass indicator of the water level,
the loading process finishes and the red light gets off. 4)
Connect
the irons with the tubes for the steam situated on the electric valves
and switch on the buttons iron. 5)
Wait till
the manometer (that indicates the pressure inside the boiler) reaches 3.5/4 bar. 6)
Press the
button for the steam. 7)
During
the ironing process it is normal if the red light gets on every now and again. EVENTUAL
POSSIBLE PROBLEMS Every
times something happens during the ironing process, you always have to turn off
the boiler buttons, plug off the generator, slightly unscrew the boiler cap and
let the steam go out before doing anything else. 1)
If the first loading process lasts more then 4 minutes, the red light begins to
flash and you will hear an alarm sound. Check
that the water flows in the tube and that the tube is well connected. Switch
off the boiler button and after checking what mentioned above, switch it on
again. 2)
If during the ironing process, the red light begins to flash and the alarm sound
gets on again, it means that the loading process lasted more than 1 minute. Switch
off the boiler button, slightly unscrew the boiler cap and let the steam go out
before doing anything else. Check that the water flows in the tube and that the
tube is well connected. Screw in the cap and switch on the boiler button. 3)
If the red light gets on and the pump keeps on loading water even if the probe
inside the glass indicator of the water level is covered by water, it means that
the water in the glass indicator is demineralized. Switch
off the boiler button, unplug the water tube, completely empty the boiler by
opening the tap situated under the boiler; close the tap, plug in the water tube
again and switch on the boiler button. 4)
If the pump makes a strange noise and doesnt load water, it means that the
pump has sucked air up. In this case you must switch the boiler button off,
slightly unscrew the cap and let all the steam go out. Check that the tube for
loading water is well connected and that the water actually flows inside it,
screw the cap and switch on the boiler button. N.B. The boiler power is 3000 Watt (almost 14 ampere), the two irons have a power of 1600 WATT (almost 8 ampere). Be careful when you connect the 2 plugs, its better if you plug them separately. MAINTENANCE Its
advisable to periodically rinse the boiler for a better and longer performance. You
should rinse it once a week, opening the tap situated under the boiler. The
warranty does not cover damages caused by kalk, due to the fact that the boiler
has not been rinsed. It
also does not cover damages due to incorrect use. |