detail:
category:
main:
|
User's
instructions for Art. PG 025 ·
Unscrew the security cap
and fill in the boiler with max. 7 lt of water, then close the cap. ·
Connect the first iron plugging it in the outlet "iron 1" .
Connect the steam cable plugging it in the special outlet situated on the left
solenoid valve. ·
Connect the second iron plugging it in the outlet "iron 2" .
Connect the steam cable plugging it in the special outlet situated on the right
solenoid valve. ·
Plug the steam generator in the main ·
Switch on the boiler by pressing the button "boiler" and the
irons by pressing the buttons "iron 1" and "iron 2" ·
Put the temperature regulator on the position "°°°" ·
Wait till the manometer reaches 3.5 bar (about 15 min.) ·
Press the steam button on the iron handle and regulate the desired steam
quantity by the handles situated behind the solenoid valves ·
Every 10 min. check the water level ·
If during ironing the steam flux ceases, it means that there's no more
water in the boiler. In order to start ironing again, switch off the
"boiler" buttons, slowly unscrew the security cap, verifying before
unscrewing it completely that there is no more steam in the irons. To verify
this, just press the red steam button situated on the irons. Plug off the
machine and fill in the boiler with water. NOTE: ·
Never leave the machine
unattended when it's plugged in. ·
The iron reaches high temperatures and maintain them for about 15 minutes
also after it has been plugged out. Be careful so that you don't get burnt. ·
The feeding plug must be disconnected from the outlet before filling in
the tank with water. ·
Never remove the tank locking cap while the machine is running and always
check, before removing it, that no steam is coming out of the iron. ·
The machine is provided with a thermal stop mechanism which must only be
replaced by authorised technicians. Therefore, if you need to replace it, please
contact one of our help desks. ·
The tank locking cap must be replaced with original spare parts. For a longer life and better machine performance, we
suggest that you use only normal water. To clean the tank from limestone, we
suggest that you periodically rinse it only with normal water (once a week). MAINTENANCE: This type of tank allows you to carry out the
maintenance by yourself. Pour in at least 5 lt of tap water, check that no more
steam comes out of the irons and then unscrew the cap underneath the generator. The guarantee does not cover damages due to not rinsing
the boiler. |
GEMME s.r.l. / L'EL.IT.™ via del lavoro 47 I-25045 Castegnato (BS) Italy tel. +39 0302141199 fax. +39 0302147637 P.iva 03426920173 info lelit@lelit.com |